United Kingdom, London

Fulham Football Club

Installing piles to support the redevelopment of the Riverside Stand
Martello were contracted by O'Keefe Construction to install 27no. 600mm diameter bearing piles to depths of up to 30m

Technical Specifications

Pile Type: Bearing

Number of Piles: 27no.

Diameter: 600/750/900mm 

Depth: 20m - 30m

The Challenge

The redevelopment of the Riverside Stand at Fulham Football Club will see an increase in capacity from 25,700 to 29,600 and enhance local amenities. The new stand will feature a new river wall a public riverside walk.

Access to the Hammersmith site was adjacent to the existing stand and had a restricted clearance that could only be achieved using a smaller rotary bored piling rig. Once into site, the piles were required to be installed beneath the existing stand within just 12m of headroom.  

The Solution

Martello were contracted by O'Keefe Construction to install 27no. 600mm diameter bearing piles to depths of up to 30m. 

Utilising the bespoke MP6001 piling rig, Martello were able to complete the 600mm diameter piles beneath the existing stand within 12m of headroom. The remaining 750 & 900mm diameter piles were installed and once completed, a static load test was carried out to determine the bearing capacity of the deep foundations prior to the redevelopment of the Riverside Stand. 

The MP6001 was best suited to this project due to its footprint being much smaller than conventional rigs. 

Project details

Project nameFulham Football Club
LocationLondon United Kingdom
Building period2019 - 2019
CategoryStadium
Contract typeBuild

Related projects